Home > Technology & Engineering > Technology: general issues > Engineering: general > Interim Testing Protocols for Determining the Seismic Performance Characteristics of Structural and Nonstructural Components (FEMA 461 / June 2007)
Interim Testing Protocols for Determining the Seismic Performance Characteristics of Structural and Nonstructural Components (FEMA 461 / June 2007)

Interim Testing Protocols for Determining the Seismic Performance Characteristics of Structural and Nonstructural Components (FEMA 461 / June 2007)

          
5
4
3
2
1

International Edition


Premium quality
Premium quality
Bookswagon upholds the quality by delivering untarnished books. Quality, services and satisfaction are everything for us!
Easy Return
Easy return
Not satisfied with this product! Keep it in original condition and packaging to avail easy return policy.
Certified product
Certified product
First impression is the last impression! Address the book’s certification page, ISBN, publisher’s name, copyright page and print quality.
Secure Checkout
Secure checkout
Security at its finest! Login, browse, purchase and pay, every step is safe and secured.
Money back guarantee
Money-back guarantee:
It’s all about customers! For any kind of bad experience with the product, get your actual amount back after returning the product.
On time delivery
On-time delivery
At your doorstep on time! Get this book delivered without any delay.
Quantity:
Add to Wishlist

About the Book

One of the primary goals of the Department of Homeland Security's Federal Emergency Management Agency (FEMA) is prevention or mitigation of this country's losses from hazards that affect the built environment. To achieve this goal, we as a nation must determine what level of performance is expected from our buildings during a severe event, such as an earthquake. To do this, several years ago FEMA contracted with the Applied Technology Council (ATC) to develop next-generation performance-based seismic design guidelines, which would allow stakeholders and their representatives to assess the probable seismic performance of new and existing buildings, and to be able to design or improve their structures to meet their performance goals. These guidelines could be voluntarily used by engineers and designers to: (1) assess and improve the performance of buildings that are currently designed to a building code "life safety" level, which would, in all likelihood, still suffer significant structural and nonstructural damage in a severe event; and (2) more effectively meet the performance targets of current building codes by providing verifiable alternatives to current prescriptive code requirements. This program is based on a long-term plan published as FEMA 445, which was developed with the input of the nation's leading seismic professionals. One of the key requirements in performance based seismic design is the ability to test and evaluate the intended performance of the various structural and nonstructural components that make up a building. The Applied Technology Council (ATC), with funding from the Federal Emergency Management Agency (FEMA), Department of Homeland Security, commenced work on a multi-year project to development performance-based seismic design guidelines for eventual incorporation in existing standards for the seismic design of new buildings and the upgrade of existing buildings (ATC-58 project). The plan for development of the guidelines is defined in the companion FEMA 445 report, Next-Generation Performance-Based Seismic Design Guidelines, Program Plan for New and Existing Buildings, which was prepared under the ATC-58 project and published by FEMA in 2006. As part of the initial work on the ATC-58 project, interim recommended protocols (documented herein) were developed for testing of structural and nonstructural components and systems found in buildings, for the purpose of establishing their seismic performance characteristics. The protocols were developed through a cooperative effort of ATC and the three National Science Foundation-funded Earthquake Engineering Research Centers (EERCs): the Mid-America Earthquake (MAE) Center at the University of Illinois, Urbana; the Multidisciplinary Center for Earthquake Engineering Research (MCEER), University at Buffalo, The State University of New York; and the Pacific Earthquake Engineering Research (PEER) Center at the University of California, Berkeley. Two interim protocol types are provided in this document: Interim Protocol I - Quasi-Static Cyclic Testing, which should be used for the determination of performance characteristics of components whose behavior is primarily controlled by the application of seismic forces or seismic-induced displacements (e.g., cladding panels, glazing panels, drywall partitions, piping and ducting system connections, ducts, and various types of anchors and braces); and Interim Protocol II - Shake Table Testing, which should be used to assess performance characteristics of components whose behavior is affected by the dynamic response of the component itself, or whose behavior is velocity sensitive, or sensitive to strain-rate effects (e.g., mechanical and electrical equipment).


Best Sellers



Product Details
  • ISBN-13: 9781484019481
  • Publisher: Createspace Independent Publishing Platform
  • Publisher Imprint: Createspace Independent Publishing Platform
  • Height: 280 mm
  • No of Pages: 138
  • Series Title: English
  • Weight: 335 gr
  • ISBN-10: 1484019482
  • Publisher Date: 02 Apr 2013
  • Binding: Paperback
  • Language: English
  • Returnable: N
  • Spine Width: 8 mm
  • Width: 216 mm


Similar Products

How would you rate your experience shopping for books on Bookswagon?

Add Photo
Add Photo

Customer Reviews

REVIEWS           
Click Here To Be The First to Review this Product
Interim Testing Protocols for Determining the Seismic Performance Characteristics of Structural and Nonstructural Components (FEMA 461 / June 2007)
Createspace Independent Publishing Platform -
Interim Testing Protocols for Determining the Seismic Performance Characteristics of Structural and Nonstructural Components (FEMA 461 / June 2007)
Writing guidlines
We want to publish your review, so please:
  • keep your review on the product. Review's that defame author's character will be rejected.
  • Keep your review focused on the product.
  • Avoid writing about customer service. contact us instead if you have issue requiring immediate attention.
  • Refrain from mentioning competitors or the specific price you paid for the product.
  • Do not include any personally identifiable information, such as full names.

Interim Testing Protocols for Determining the Seismic Performance Characteristics of Structural and Nonstructural Components (FEMA 461 / June 2007)

Required fields are marked with *

Review Title*
Review
    Add Photo Add up to 6 photos
    Would you recommend this product to a friend?
    Tag this Book
    Read more
    Does your review contain spoilers?
    What type of reader best describes you?
    I agree to the terms & conditions
    You may receive emails regarding this submission. Any emails will include the ability to opt-out of future communications.

    CUSTOMER RATINGS AND REVIEWS AND QUESTIONS AND ANSWERS TERMS OF USE

    These Terms of Use govern your conduct associated with the Customer Ratings and Reviews and/or Questions and Answers service offered by Bookswagon (the "CRR Service").


    By submitting any content to Bookswagon, you guarantee that:
    • You are the sole author and owner of the intellectual property rights in the content;
    • All "moral rights" that you may have in such content have been voluntarily waived by you;
    • All content that you post is accurate;
    • You are at least 13 years old;
    • Use of the content you supply does not violate these Terms of Use and will not cause injury to any person or entity.
    You further agree that you may not submit any content:
    • That is known by you to be false, inaccurate or misleading;
    • That infringes any third party's copyright, patent, trademark, trade secret or other proprietary rights or rights of publicity or privacy;
    • That violates any law, statute, ordinance or regulation (including, but not limited to, those governing, consumer protection, unfair competition, anti-discrimination or false advertising);
    • That is, or may reasonably be considered to be, defamatory, libelous, hateful, racially or religiously biased or offensive, unlawfully threatening or unlawfully harassing to any individual, partnership or corporation;
    • For which you were compensated or granted any consideration by any unapproved third party;
    • That includes any information that references other websites, addresses, email addresses, contact information or phone numbers;
    • That contains any computer viruses, worms or other potentially damaging computer programs or files.
    You agree to indemnify and hold Bookswagon (and its officers, directors, agents, subsidiaries, joint ventures, employees and third-party service providers, including but not limited to Bazaarvoice, Inc.), harmless from all claims, demands, and damages (actual and consequential) of every kind and nature, known and unknown including reasonable attorneys' fees, arising out of a breach of your representations and warranties set forth above, or your violation of any law or the rights of a third party.


    For any content that you submit, you grant Bookswagon a perpetual, irrevocable, royalty-free, transferable right and license to use, copy, modify, delete in its entirety, adapt, publish, translate, create derivative works from and/or sell, transfer, and/or distribute such content and/or incorporate such content into any form, medium or technology throughout the world without compensation to you. Additionally,  Bookswagon may transfer or share any personal information that you submit with its third-party service providers, including but not limited to Bazaarvoice, Inc. in accordance with  Privacy Policy


    All content that you submit may be used at Bookswagon's sole discretion. Bookswagon reserves the right to change, condense, withhold publication, remove or delete any content on Bookswagon's website that Bookswagon deems, in its sole discretion, to violate the content guidelines or any other provision of these Terms of Use.  Bookswagon does not guarantee that you will have any recourse through Bookswagon to edit or delete any content you have submitted. Ratings and written comments are generally posted within two to four business days. However, Bookswagon reserves the right to remove or to refuse to post any submission to the extent authorized by law. You acknowledge that you, not Bookswagon, are responsible for the contents of your submission. None of the content that you submit shall be subject to any obligation of confidence on the part of Bookswagon, its agents, subsidiaries, affiliates, partners or third party service providers (including but not limited to Bazaarvoice, Inc.)and their respective directors, officers and employees.

    Accept

    New Arrivals



    Inspired by your browsing history


    Your review has been submitted!

    You've already reviewed this product!